Issue
J. Phys. III France
Volume 7, Number 8, August 1997
Page(s) 1735 - 1740
DOI https://doi.org/10.1051/jp3:1997215
DOI: 10.1051/jp3:1997215
J. Phys. III France 7 (1997) 1735-1740

Improvement of the Spatial Amplitude Isotropy of a 4He Magnetometer Using a Modulated Pumping Beam

B. Chéron1, 2, H. Gilles1, J. Hamel1, O. Moreau1 and E. Noël1

1  Laboratoire de Spectroscopie Atomique, ISMRA, 14050 Caen cedex, France
2  Université de Caen, UFR de Sciences, 14032 Caen cedex, France

(Received 24 January 1997, revised 5 May 1997, accepted 7 May 1997)

Abstract
Optically pumped magnetometers are scalar magnetometers. Contrary to vectoriel magnetometers, they measure the total magnetic field whatever the direction of the sensor. However, for some orientations of the magnetometer with respect to the magnetic field direction, the resonant signal vanishes and the measurement is impossible. In this paper we present a simple solution to reduce the amplitude spatial anisotropy and apply it to a 4He magnetometer developed in our Laboratory.

Résumé
Les magnétomètres à pompage optique sont des magnétomètres scalaires. Contrairement aux magnétomètres vectoriels, ils mesurent le module du champ magnétique quelle que soit l'orientation du capteur dans l'espace. Cependant, pour certaines orientations du magnétomètre par rapport à la direction du champ à mesurer, l'amplitude du signal de résonance s'annule et la mesure devient impossible. Dans cet article, nous présentons une solution simple pour réduire l'anisotropie spatiale d'amplitude et nous l'appliquons à un magnétomètre à hélium-4 développé dans notre Laboratoire.



© Les Editions de Physique 1997