Abstract
We describe the state of the art of pulse tube refrigerator. Experiments have been performed showing that the heat exchanges between the gas and the walls are more important in the basic pulse tube than in the orifice pulse tube. We show that the ratio $R/\delta$ determines the amount of heat exchanges. Then, we subsequently describe the pulse tube operation with emphasis on gas to gas heat exchanges. We show qualitatively that heat exchanges separate from hot and cold heat exchangers, must exist.

Résumé
L'article fait le point sur le tube à gaz pulsé. Nous avons réalisé des expériences qui nous ont permis de montrer que les échanges de chaleur entre le gaz et la paroi du tube sont plus efficaces dans un tube fermé que dans un tube avec orifice. Nous montrons que le rapport $R/\delta$ caractérise correctement ces échanges de chaleur. Nous rappelons ensuite le concept des échanges gaz-gaz et montrons qualitativement qu'il doit exister d'autres échanges de chaleur que ceux existant au niveau des échangeurs chaud et froid. Enfin l'article décrit le système à un étage qui nous a permis d'atteindre une température de 70 K avec une puissance de 4 W à 85 K.