Numéro |
J. Phys. III France
Volume 1, Numéro 2, February 1991
|
|
---|---|---|
Page(s) | 173 - 177 | |
DOI | https://doi.org/10.1051/jp3:1991115 |
J. Phys. III France 1 (1991) 173-177
Etat d'avancement d'un nouveau type de réfrigérateur : le tube a gaz pulsé
Marc David1, 2 and Jean-Claude Maréchal11 Ecole Normale Supérieure, Laboratoire de Radioastronomie, Paris, France
2 CRYOPHYSICS S.A., Jouy en Josas, France
(Reçu le 16 mars 1990, accepté le 11 octobre 1990)
Abstract
We describe the state of the art of pulse tube refrigerator. Experiments have been performed showing that the heat exchanges
between the gas and the walls are more important in the basic pulse tube than in the orifice pulse tube. We show that the
ratio
determines the amount of heat exchanges. Then, we subsequently describe the pulse tube operation with emphasis on gas to
gas heat exchanges. We show qualitatively that heat exchanges separate from hot and cold heat exchangers, must exist.
Résumé
L'article fait le point sur le tube à gaz pulsé. Nous avons réalisé des expériences qui nous ont permis de montrer que les
échanges de chaleur entre le gaz et la paroi du tube sont plus efficaces dans un tube fermé que dans un tube avec orifice.
Nous montrons que le rapport
caractérise correctement ces échanges de chaleur. Nous rappelons ensuite le concept des échanges gaz-gaz et montrons qualitativement
qu'il doit exister d'autres échanges de chaleur que ceux existant au niveau des échangeurs chaud et froid. Enfin l'article
décrit le système à un étage qui nous a permis d'atteindre une température de 70 K avec une puissance de 4 W à 85 K.
© Les Editions de Physique 1991