Numéro |
J. Phys. III France
Volume 3, Numéro 4, April 1993
|
|
---|---|---|
Page(s) | 883 - 809 | |
DOI | https://doi.org/10.1051/jp3:1993170 |
J. Phys. III France 3 (1993) 883-809
Les erreurs sur la diffusivité thermique mesurée par méthode flash : confrontation théorie-expérience
D. Maillet, S. André and A. DegiovanniLEMTA-ENSEM, URA CNRS 875, 2 av. de la Forêt de Haye, 54516 Vandoeuvre-les-Nancy Cedex, France
(Reçu le 30 juillet 1992, révisé le 8 janvier 1993, accepté le 14 janvier 1993)
Abstract
The two methods of the partial times and of the partial time moments, that rely on an
analytical model, allow the processing of a thermogram produced in a heat pulse (flash)
experiment in order to measure the thermal diffusivity of a material. Using a stochastic
approach, it is shown that the characteristics of the digitized measurement noise can
lead to the calculation of the standard deviations of the estimations of both diffusivity
and Biot number related to heat losses. Repetition of flash experiments on a same sample
allows, using a statistical study, to validate the preceding theoretical analysis and
to conclude that the second method is superior.
Résumé
Les deux méthodes des temps partiels et des moments temporels partiels, qui sont basées
sur un modèle analytique, permettent de traiter le thermogramme issu d'une expérience
flash qui est destinée à mesurer la diffusivité thermique d'un matériau. Par une
approche stochastique, on montre comment l'on peut passer des caractéristiques du
bruit de mesure numérisé du détecteur de température aux écart-types des estimateurs
de la diffusivité et du nombre de Biot relatif aux pertes. La répétition d'expériences
flash sur un même échantillon permet, par une étude statistique, de valider l'analyse
théorique précédente et de conclure à la supériorité de la deuxième méthode.
© Les Editions de Physique 1993