Numéro |
J. Phys. III France
Volume 4, Numéro 10, October 1994
|
|
---|---|---|
Page(s) | 2013 - 2029 | |
DOI | https://doi.org/10.1051/jp3:1994254 |
J. Phys. III France 4 (1994) 2013-2029
The subsonic chemical oxygen-iodine laser : comparison of a theoretical model to experiments in the 30 W range
S. Churassy, A. J. Bouvier, A. Bouvier, B. Erba and M. SetraLaboratoire de Spectrométrie Ionique et Moléculaire (URA n$^{\circ}$ 171), CNRS et Université Lyon I, Bât. 205, 43 Bd du 11 Novembre 1918, 69622 Villeurbanne Cedex, France
(Received 28 February 1994, revised 11 May 1994, accepted 14 June 1994)
Abstract
The performances of a small scale subsonic chemical oxygen-iodine laser have been improved, the output laser power being increased
from 5 to 34 W, with the same gas pumping system. At this power range, we have shown that the modeling of the laser must include
the temperature effects on the reaction kinetics. Our model shows also that the addition of a buffer gas such as SF
6 achieves a significant cooling of the active medium, which in turn allows a better laser power extraction.
Résumé
Les performances d'un laser subsonique à iode-oxygène chimique à petite échelle ont été améliorées, la puissance laser étant
augmentée de 5 W à 34 W avec le même ensemble de pompage. Nous avons montré que, dans ce domaine de puissance, la modélisation
du laser doit inclure les effets de température sur les cinétiques des réactions. Notre modèle montre également que l'adjonction
d'un gaz tampon tel que SF
6 conduit à un refroidissement important du milieu actif, permettant alors une meilleure extraction de la puissance laser.
© Les Editions de Physique 1994