Étude de la sensibilité d'un capteur de pression à quartz à distribution radiale

R. Delaite

E.N.S.M.M., Équipe de Physique et Électronique des Capteurs, 26 chemin de l'Épitaphe, 25030 Besançon Cedex, France

(Reçu le 6 juillet 1995, accepté le 15 décembre 1995)

Abstract
An analysis is presented to determine the sensitivity of a piezoelectric pressure sensor in the case of a resonator subject to radial compression uniformly distributed over an angular part of the crystal edge. For a cut crystal singly rotated and for a doubly rotated, a coefficient of pressure sensitivity is calculated and gives the advantage of introducing the optimal value of the angular sector, as well as the azimut of application of the pressure. This solution becomes particularly interesting if one applies it to a singly rotated AT-cut crystal.

Résumé
Une étude est effectuée pour déterminer la sensibilité d'un capteur de pression à quartz dans le cas d'une distribution uniforme de la pression selon un secteur angulaire à la périphérie du cristal. Un coefficient de sensibilité à la pression est calculé pour des coupes à simple ou double rotation. Il permet d'introduire une valeur optimale du secteur angulaire et de sa position dans le repère du cristal. Cette solution devient intéressante pour le capteur si on utilise une coupe AT.



© Les Editions de Physique 1996