Numéro
J. Phys. III France
Volume 7, Numéro 10, October 1997
Page(s) 1967 - 1973
DOI https://doi.org/10.1051/jp3:1997235
DOI: 10.1051/jp3:1997235
J. Phys. III France 7 (1997) 1967-1973

Analyse de l'effet des courants induits sur l'impédance d'un système électromagnétique alimenté en tension BF ou HF. Utilisation de la méthode des circuits couplés

B. Maouche1 and M. Feliachi2

1  Centre Universitaire, 06000 Bejaïa, Algérie
2  GE44 - (LRTI-IUT), CRTT, BP. 406, 44602 Saint-Nazaire Cedex, France

(Reçu le 20 mars, accepté le 7 juillet)

Abstract
In this paper, a study of the interaction between the inductor and the load of an axisymmetrical induction device is proposed. This interaction concerns the effect of the eddy current on both the excitation current and on the system impedance. A half analytical model, based on a numerical discretization of the electromagnetic solution domain, is used. In each cell of the numerical discretization, an analytical calculation using the Moment Method (MM) is considered. In the case of strong skin effect (High Frequency: HF), the formulation makes use of the Impedance Boundary Condition (IBC); in the contrary case (Low Frequency: LF), the interior domain is discretized.

Résumé
Dans cet article nous proposons l'étude de l'influence d'une charge (induit) conductrice sur la répartition du courant inducteur ainsi que sur l'impédance du système. L'inducteur est à géométrie axisymétrique de forme solénoïdale ou pancake destiné au chauffage par induction. Une méthode semi-analytique, basée sur une discrétisation du domaine en mailles élémentaires auxquelles s'applique une formulation intégrale (Méthode des Circuits Couplés : MCC) des grandeurs électromagnétiques, est utilisée. Dans le cas où l'effet de peau est important (Haute Fréquence : HF), la formulation associe la Condition d'Impédance de Surface; dans le cas contraire (Basse Fréquence : BF), un maillage du domaine interne est pratiqué.



© Les Editions de Physique 1997